9.11
Section 9
Disassembly
9
Figure 9-43. Remove Bracket and Stator.
Remove Closure Plate
1. Remove the hex ange screws securing the
closure plate to the crankcase. See Figures 9-44
and 9-45.
Hex
Hex
Screws
Screws
Figure 9-44. CH270 Closure Plate Mounting
Screws.
Hex
Hex
Screws
Screws
Figure 9-45. CH395, CH440 Closure Plate Mounting
Screws.
2. Remove the closure plate gasket and dowel pins
if required from the crankcase. See Figures 9-46
and 9-47.
NOTE: Do not pry on the gasket surface of the
crankcase or closure plate, as this can
cause damage and leakage.
Dowel Pins
Dowel Pins
Figure 9-46. CH270 Closure Plate Gasket and
Dowel Pins.
Figure 9-47. CH395, CH440 Closure Plate Dowel
Pins.
3. Remove the shims from the cranksha and
camsha .
Remove Balance Shaft (If Equipped)
1. Remove the balance sha by pulling it straight
out of the crankcase. See Figure 9-48.
Stator
Stator
Stator Wire
Stator Wire
Bracket
Bracket
Dowel Pins
Dowel Pins

Table of Contents

Other manuals for Kohler Command PRO CH260

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler Command PRO CH260 and is the answer not in the manual?

Kohler Command PRO CH260 Specifications

General IconGeneral
BrandKohler
ModelCommand PRO CH260
CategoryEngine
LanguageEnglish

Related product manuals