100
Section 6 Decision-Makerr 3000 Controller TP-6356 4/12
Programmer-Defined Settings
Description
Controller Display
Message
Write
Access
Display
Si
teTech
GenSet
Mode
Always
R
unning
S
topped
Range
Setting
Default
Selection
Time
Delay
Range
(sec.)
Default
Time
Delay
(sec.)
Programmer-
Defined
Settings
Engine Functions
Critically high fuel level
(diesel-powered models only) *
Fuel Level Critically
High
0--100% 95% 0--10 5
ECM communications loss ECMCommErr
Shutdwn
Fixed 10 Not adjustable
ECM diagnostics (multiple
inputs) [
ECM xxxxxx Warning Not adjustable
ECM diagnostics (multiple
inputs) [
ECM xxxxxx Shutdwn Not adjustable
ECM faults (address conflict) ECM Addr Err
Shutdwn
Not adjustable
ECM faults (model mismatch) ECM Mismatch
Shutdwn
0--255 0
Engine over speed Eng Speed High
Shutdwn
S A 105--120% 115%
Engine start aid active Starting Aid Notice
Engine under speed Eng Speed Low
Shutdwn
S A 75--95% 85%
Fuel tank leak * Fuel Leak Warning Not adjustable
Fuel tank leak * Fuel Leak Shutdwn Not adjustable
High battery voltage Battery High Warning S A 110--135% 125% Fixed 10 Not adjustable
High coolant temperature
Coolnt Temp High
Warning
0--10
(0--30
inhibit)
0
(0
inhibit)
High coolant temperature
Coolnt Temp High
Shutdwn
0--10
(0--30
inhibit)
0
(0
inhibit)
High fuel level (diesel-powered
models only) *
Fuel Level High
Warning
0--100% 90% 0--10 5
Low battery voltage Battery Low Warning S A 80--105% 100% Fixed 90 Not adjustable
Low coolant level * Coolant Lvl Low
Shutdwn
Fixed 5 Not adjustable
Low coolant temperature
Coolant Temp Low
Warning
Fixed
16_C
(60_F)
0--10
(0--30
inhibit)
5
(0
inhibit)
Low cranking voltage Lo Crank Vlt Warning Fixed 60% Fixed 6 Not adjustable
Low engine oil level * Oil Level Low Warning Not adjustable
Low engine oil level * Oil Level Low Shutdwn Not adjustable
Low fuel level (diesel models) * Fuel Level Low
Warning
0--100% 35% 0--10 10
Low fuel level (diesel models) * Fuel Level Low
Shutdwn
0--100% 5% 0--10 0
Low fuel pressure
(gas models) *
Fuel Press Low
Warning
Not adjustable
Low oil pressure
Oil Press Low Warning
Fixed
(Fixed
inhibit)
0
(30
inhibit)
Not adjustable
Low oil pressure
Oil Press Low
Shutdwn
Fixed
(Fixed
inhibit)
5
(30
inhibit)
Not adjustable
No coolant temperature signal Temp Sig Loss
Shutdwn
Not adjustable
No oil pressure signal Press Sig Loss
Shutdwn
Fixed 5 Not adjustable
Overcrank
Over Crank Shutdwn Fixed
(30
inhibit)
Not adjustable
Speed sensor fault Spd Sens Flt Warning Not adjustable

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler Decision-Maker 1 and is the answer not in the manual?

Kohler Decision-Maker 1 Specifications

General IconGeneral
BrandKohler
ModelDecision-Maker 1
CategoryPortable Generator
LanguageEnglish

Related product manuals