SERVICE PROCEDURE MAINTENANCE
4-36
CHECK IDLER OIL LEVEL, ADD OIL
WARNING
If the oil level in the idler is low, new oil must be added, and the machine body must be inclined in this
case. Since this work is dangerous, ask your Komatsu distributor.
If the oil level in the idler is low, noise will be generated and there will be seizure, so check the oil level and add oil
as follows.
INSPECTION
1. Remove bolt(1), then remove guide plate(2) and shim(3).
REMARK
When removing shim(3) keep it in a safe place and be careful
not to lose it.
2. Loosen plug(4) slowly. If oil oozes through the threads at
this time, the quantity of oil is sufficient. Tighten plug(4).
3. If any oil does not flow out when plug(4) is removed, the
quantity of oil is insufficient. In this case, ask your
Komatsu distributor for repair.
4. Install guide plate(2) and shim(3) with bolt(1).
REMARK
When installing guide plate(2), install the same number and
thickness of shim(3) as was removed in Step 1.
For details of adjusting the shim thickness, see "ADJUST
IDLER CLEARANCE (PAGE 4-30)".