SERVICE PROCEDURE MAINTENANCE
4-52
EVERY 1000 HOURS SERVICE
Maintenance for every 50, 250 and 500 hours should be carried out at the same time.
CHANGE OIL IN POWER TRAIN CASE, CLEAN STRAINERS (POWER TRAIN
STRAINER, SCAVENGING PUMP STRAINER)
WARNING
● The oil is at high temperature immediately after the machine has been operated. Wait for the oil to
cool down before starting the operation.
● The undercover is heavy. Never try to open or close the cover when directly beneath it. When remov-
ing bolts(2), carry out the work from the rear below the cover so that you can easily get out of the way.
● Container to catch drained oil: Min 50 liters capacity
● Refill capacity: 50 liters (13.2US gal)
1. Loosen drain plug(P) (with a slit), drain the oil, then
tighten drain plug(P) again.
Do not remove drain plug(P).
2. Remove the undercover from the rear bottom of the
machine body according to the following procedure.
1) Remove two bolts(1) from the front side of the
machine body.
2) Holding the cover, remove two bolts(2) from the rear
side of the machine body.
3) Lower and open the cover gradually.
Weight of undercover: 21kg (46lb)