HANDLING TOWING WINCH ATTACHMENTS, OPTIONS
6-18
EVERY 1000 HOURS SERVICE
CHANGE GEAR CASE OIL AND CLEAN STRAINER
WARNING
The oil is at high temperature after the machine has been operated. Always wait for the temperature to go
down before starting this operation.
Prepare the following.
Container to catch drained oil: Min. 76 liters (20.06 US gal) capacity
Refill capacity: 76 liters (20.06 US gal)
1. Set the container to catch the oil immediately under drain
plug (P).
2. Loosen drain plug (P), drain the oil, then tighten drain
plug (P) again.
3. Remove strainer cover (H), then take out strainer (J) and
case (K) and clean them.
NOTICE
After washing the strainer with flushing oil, blow it with
compressed air to completely remove all the dirt.
4. Install strainer (J), case (K), and strainer cover (H), then
add engine oil through oil filler (F).
NOTICE
Use oil to match the ambient temperature.
More than 0
°C(32°F): Engine oil CD Class SAE30W
Less than 0
°C(32°F): Engine oil CD Class SAE10W