68 TROUBLESHOOTING
BATTERY TROUBLESHOOTING
If you have any questions, consult your local KUBOTA Dealer.
Trouble Cause Countermeasure Preventive measure
Starter does not function.
A Battery overused until
lights are dim.
A Charge battery
sufficiently.
A Charge the battery properly.
A Battery has not been
recharged.
A Poor terminal
connection.
A Clean the terminal
and tighten securely.
A Keep the terminal clean and
tight.
Apply grease and treat with
anti-corrosives.
A Battery life expired. A Renew battery.
From beginning starter
does not function, and
lights soon become dim.
A Insufficient charging. A Charge battery
sufficiently.
A Battery must be serviced
properly before initial use.
When viewed from top,
the top of plates look
whitish.
A Battery was used with
an insufficient amount
of electrolyte.
A Add distilled water
and charge the
battery.
A Regularly check the
electrolyte level.
A Battery was used too
much without
recharging.
A Charge battery
sufficiently.
A Charge the battery properly.
Recharging is impossible.
A Battery life expired. A Replace battery.
Terminals are severely
corroded and heat up.
A Poor terminal
connection.
A Clean the terminal
and tighten securely.
A Keep the terminal clean and
tight.
Apply grease and treat with
anti-corrosives.
Battery electrolyte level
drops rapidly.
A There is a crack or pin
holes in the electrolytic
cells.
A Replace battery.
A Charging system
trouble.
A Consult your local
KUBOTA Dealer.