5. FUEL SYSTEM
5-10
PEOPL E 12 5/150
FLOAT LEVEL INSPECTION
Measure the float level.
Float Level: 18.5mm
Float Level Gauge
CARBURETOR INSTALLATION
Tighten the drain screw.
Install the carburetor onto the intake
manifold, aligning the tab on the carburetor
with the cutout in the intake manifold.
Tighten the band screw.
Install the air cleaner connecting tube and
tighten the band screw.
Connect the throttle cable to the throttle
wheel on the carburetor.
Connect the fuel tube and vacuum tube to the
carburetor.
Connect the auto bystarter wire connector.
Perform the following inspections and
adjustments:
-Throttle grip free play (
!
3-3)
-Carburetor idle speed (
!
3-6)
Special
Auto Bystarter Wire
Connector
Vacuum Tube
Float Valve
Connecting Tube Band
Throttle Cable
Check the operation of the float valve
and float before float level inspection.
Measure the float level by placing the
float level gauge on the float chamber
face parallel with the main jet.
Float Level Gauge
Float Pin
www.PlanDeGraissage.org

Table of Contents

Other manuals for KYMCO PEOPLE 150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KYMCO PEOPLE 150 and is the answer not in the manual?

KYMCO PEOPLE 150 Specifications

General IconGeneral
BrandKYMCO
ModelPEOPLE 150
CategoryScooter
LanguageEnglish

Related product manuals