14. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
14-7
PEOPL E 12 5/150
A.C. GENERATOR CHARGING
COIL
INSPECTION
Disconnect the A.C. generator 3P connector.
Measure the resistance between the A.C.
generator white wire and engine ground with
an electric tester.
Standard: 0.2_ 1.2W(at 20 )
Replace the A.C. generator charging coil if the
reading is not within the specifications.
A.C. GENERATOR LIGHTING
COIL
INSPECTION
Disconnect the A.C. generator 3P connector.
Measure the resistance between the A.C.
generator yellow wire and engine ground with
an electric tester.
Standard: 0.2_ 1.2W(at 20 )
Replace the A.C. generator lighting coil if the
reading is not within the specifications.
RESISTOR INSPECTION
Remove the front cover. (
!
2-4)
Measure the resistance between the resistor
lead and engine ground.
Resistances: 30W7.5W: 7.0_ 8.0W
5W5.0W: 4.0_ 6.0W
A.C. GENERATOR
REMOVAL
Remove the rear right side cover. (
!
2)
Remove the four bolts attaching the cooling
fan cover to remove the fan cover.
The inspection of A.C. generator
charging coil can be made with the engine
installed.
The inspection of A.C. generator lighting
coil can be made with the engine
installed.
Charging Coil Wire (White)
Lighting Coil Wire (Yellow)
Resistor
Fan Cover
Bolts
www.PlanDeGraissage.org

Table of Contents

Other manuals for KYMCO PEOPLE 150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KYMCO PEOPLE 150 and is the answer not in the manual?

KYMCO PEOPLE 150 Specifications

General IconGeneral
BrandKYMCO
ModelPEOPLE 150
CategoryScooter
LanguageEnglish

Related product manuals