BATTERY
BATTERY REMOVAL
Remove the battery cover.
Disconnect the battery cables .
Remove the bolt and battery bracket.
Remove the battery.
The installation sequence is the reverse of
removal.
BATTERY CHARGING (OPEN CIRCUIT
VOLTAGE) INSPECTION
Remove the battery cover and disconnect the
battery cables.
Measure the voltage between the battery
terminals.
Fully charged : 13.0V 13.2V
Undercharged : 12.3V max.
CHARGING METHOD
Connect the charger positive (+) cable to the
battery positive (+) cable.
Connect the charger negative (-) cable to the
battery negative (-) cable.
Charging current : Standard : 0.4A
Quick : 4A
Charging time : Standard : 5 hours
Quick : 0.5 hour
After charging: Open circuit voltage: 12.8V min.
PERFORMANCE TEST