22
5 Display and Operational Controls
5.4 Main Menu
The following values are displayed:
•O
2
value, resolution 0.1%
•CO
e
value (recommended 1,000 ppm), resolution 1 ppm
•CO
e
: Probe signal dynamics
CO edge signal reached/exceeded
The factory-set reaction threshold lies at 40%. The display shows whether the reaction thresh-
old is reached. When the reaction threshold is reached, the CO edge signal is present and the
CO control becomes active. This is shown through a symbol in the display or can be read
via the LSB remote software in Parameter 444. The desired response threshold be set on the
display or using Parameter 453 of the LSB remote software. Access level 2 is required for ser-
vice!
Press ENTER to access the main menu.
Meaning of the symbols:
Password entry
Information regarding the probe and fuel, warnings and faults,
software version, CRC, and serial number
Calibration of measurement
Settings (maintenance, filter time, analogue output, probe replacement, display,
limit values and digital outputs)
Main display Main menu

Table of Contents

Other manuals for Lamtec KS1D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lamtec KS1D and is the answer not in the manual?

Lamtec KS1D Specifications

General IconGeneral
BrandLamtec
ModelKS1D
CategoryTransmitter
LanguageEnglish

Related product manuals