WARNING
Improper installation of the furnace can result in personal
LQMXU\ RU GHDWK &RPEXVWLRQ DQG ÀXH SURGXFWV PXVW
never be allowed to enter the return air system or air
in the living space. Use sheet metal screws and joint
tape to seal return air system to furnace. In platform
installations with furnace return, the furnace should be
sealed airtight to the return air plenum.
A door must never be used as a portion of the return air
duct system. The base must provide a stable support
and an airtight seal to the furnace. Allow absolutely
no sagging, cracks, gaps, etc. For no reason should
return and supply air duct systems ever be connected
WRRUIURPRWKHUKHDWLQJGHYLFHVVXFKDVD¿UHSODFHRU
stove, etc. Fire, explosion, carbon monoxide poisoning,
personal injury and/or property damage could result.
Installation Clearances
Top
Bottom (Floor)
Left Side Right Side
Top/Plenum 1 in. (25 mm)
*Front 0
Back 0
Sides 0
Vent 0
Floor 0
*Front clearance in alcove installation must be 24 in. (610 mm).
Maintain a minimum of 24 in. (610 mm) for front service access.
Allow proper clearances to accommodate condensate trap.
For installations on a combustible floor, do not install the furnace
directly on carpeting, tile or other combustible materials other
than wood flooring.
Figure 12
Return Air Guidelines
Return air can be brought in through the bottom or either
VLGHRIWKHIXUQDFHLQVWDOOHGLQDQXSÀRZDSSOLFDWLRQ,IWKH
furnace is installed on a platform with bottom return, make
an airtight seal between the bottom of the furnace and the
platform to ensure that the furnace operates properly and
safely. The furnace is equipped with a removable bottom
panel to facilitate installation.
Markings are provided on both sides of the furnace cab-
inet for installations that require side return air. Cut the
furnace cabinet at the maximum dimensions shown on
page 2.
5HIHUWR(QJLQHHULQJ+DQGERRNIRUDGGLWLRQDOLQIRUPDWLRQ
EL196UHE applications which include side return air
and a condensate trap installed on the same side of
the cabinet (trap can be installed remotely within 5
IWUHTXLUHHLWKHUDUHWXUQDLUEDVHRU¿HOGIDEULFDWHG
transition to accommodate an optional IAQ accessory
taller than 14.5”. See Figure 13.
Side Return Air
(with transition and filter)
Return
Air
Plenum
Transition
20” X 25” X 1”
(508mmX635mmX 25mm)
Air Filter
Figure 13

Other manuals for Lennox Elite series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox Elite series and is the answer not in the manual?

Lennox Elite series Specifications

General IconGeneral
BrandLennox
ModelElite series
CategoryFurnace
LanguageEnglish

Related product manuals