Table 12. PureAir S Parameters
Parameter Description
Max Air Filtered
between Tests
Default is 100%, Range is 50% to 100% Changes can be made
in increments of 10%. This parameter:
• Modies the amount of air that is allowed to pass through the
lter after a valid % life determination before a lter test is
initiated.
• Expressed as a percentage of the cubic feet of air that would
pass through the lter if the fan operated at continuous fan
CFM for 30 days.
UV lamp operation
detection
Default: ON. Options are either ON or OFF.
Filter Life
Provides percentage of remaining lter life. This is for display
purposes only and cannot be changed.
Last replacement
date for lter
Date last lter reset was accomplished. This is for display
purposes only and cannot be changed
Purier life
Provides percentage of remaining purier life. This is for display
purposes only and cannot be changed
Last replacement
date for purier
Date last purier insert reset was accomplished. This is for
display purposes only and cannot be changed
• Reset PureAir S will reset all PureAir S parameters back to factory defaults.
• Reset purier will reset it to 100%. This is usually accomplished after the purier insert has
been replaced.
• Reset lter will reset it to 100%. This is usually accomplished after the air lter has been
replaced.
Add/Remove Equipment
Here additional non-communicating equipment can be added. Type of
equipment that are supported are fresh air damper, 1 or 2 speed HRV/ERV,
By-pass (24VAC Humidier, Humiditrol, and auxiliary dehumidier.
Add Device
Smart Devices Network
The Lennox Smart Devices Network can only be created by using the
Lennox
®
Smart Technician Application
.
Managing Smart Devices
Smart devices can be added, replace and removed. Please refer to the
Installation and Setup Guide for each product for procedures on how to add,
replace or remove these smart devices.
Lennox Smart Room Sensor
Table 13. Lennox Smart Room Sensor (SRS)
Parameter Description
Sensor Name
This could be the default sensor name given when the sensor
was added. This eld also allows the sensor to be renamed.
Device Type Sensor
Sensor Status:
Battery This is the battery available power percentage.
RSSI Signal Strength
This indicates the bluetooth signal strength between the sensor
and the S40 thermostat or wireless extender if used.
Sensor Information:
Model Number Model number of device.
Serial Number Serial number.
Firmware Version Current rmware version of the sensor.
IMPORTANT
The Lennox Smart Room Sensor is not compatible with systems using the
Lennox Smart Zoning System (iHarmony) installed.
Lennox Smart Air Quality Monitor
Table 14. Lennox Smart Air Quality Monitor
Parameter Description
Monitor Name
This could be the default Lennox Smart Air Quality Monitor name
given when the monitor was added. This eld also allows the
monitor to be renamed.
Device Type Monitor
Level of Indoor Air
Cleanliness
Status types that can be displayed are High, Medium and Basic
(Most Economical)
Monitor Status
RSSI Signal Strength
This indicates the Bluetooth signal strength between the monitor
and the S40 thermostat or wireless extender if used.
Monitor Information
Model Number Model number of device.
Serial Number Serial number.
Firmware Version Current rmware version of the sensor.