Function library
Function blocks
3.5.68 Variable table Waiting time (VTTIME)
3−279
l
EDSVS9332P−EXT DE 2.0
3.5.68 Variable table Waiting time (VTTIME)
One function block (VTTIME) is available.
Purpose
Store values for waiting times. They are used as delays for the function "Waiting time" in the
positioning program.
VTTIME-IN1
VTTIME
C1358/1
C1359/1
VTTIME-IN2
C1358/2
C1359/2
VTTIME-IN3
C1358/3
C1359/3
VTTIME-IN4
C1358/4
C1359/4
C1305/1
VTTIME-OUT1
C1305/2
VTTIME-OUT2
C1305/3
VTTIME-OUT3
C1305/4
VTTIME-OUT4
C1305/5
...
C1305/30
VTTIME-No 1
VTTIME-No 2
VTTIME-No 3
VTTIME-No 4
VTTIME-No 5
VTTIME-No 30
VTTIME-No 31
VTTIME-No 32
VTTIME-No 33
VTTIME-No 34
C1387/x
...
Fig. 3−221 Function block VTTIME
Stop!
If times >32767 ms are entered under C1305/1 to C1305/4 the outputs VTTIME−OUT1 ...
VTTIME−OUT4 must no longer be used.
Signal Source Note
Name Type DIS DIS format CFG List
VTTIME−IN1 a C1359/1 dec [inc] C1358/1 3
· Generates the absolute value for negative values.
· Value = 100 % = 16384 ms
· Limits the value to 32767 ms
· Display: 1 inc = 1 ms
VTTIME−IN2 a C1359/2 dec [inc] C1358/2 3
VTTIME−IN3 a C1359/3 dec [inc] C1358/3 3
VTTIME−IN4 a C1359/4 dec [inc] C1358/4 3
VTTIME−OUT1 a 1 inc = 1 ms
VTTIME−OUT2 a 1 inc = 1 ms
VTTIME−OUT3 a 1 inc = 1 ms
VTTIME−OUT4 a 1 inc = 1 ms