Function library
Function blocks
3.5.23 Phase conversion (CONVPHPH2)
3−155
l
EDSVS9332P−EXT DE 2.0
3.5.23 Phase conversion (CONVPHPH2)
Purpose
Conversion of a phase signal with dynamic fracture.
C O N V P H P H 2
C O N P H P H 2 - O U T
C O N V P H P H 2 - I N
C 1 1 3 7
C 1 1 3 2
C O N V P H P H 2 - N U M
C 1 1 3 5 / 1
C 1 1 3 0 / 1
C O N V P H P H 2 - D E N
C 1 1 3 5 / 2
C 1 1 3 0 / 2
x
y
C 1 1 3 1
C 1 1 3 6
C O N V P H P H 2 - A C T
1
0
0
Fig. 3−108 Phase conversion (CONVPHPH2)
Signal
Source Note
Name Type DIS DIS format CFG List
CONVPHPH2−IN ph C1137 dec [inc] C1132 3
CONVPHPH2−NUM a C1135/1 dec C1130/1 1 Numerator
CONVPHPH2−DEN a C1135/2 dec C1130/2 1 Denominator (with absolute−value generation)
CONVPHPH2−ACT d C1136 bin C1131 2
CONVPHPH2−OUT ph Without limitation, residual value considered
Function
Caution!
The conversion result is not limited. The result must not exceed the range of ±2147483647.
l C1131 = HIGH
The phase signal at CONVPHPH2−IN is evaluated with the factor from C1135/1 / C1135/2.
l C1131 = LOW
The value 0 is evaluated with the factor from C1135/1 / C1135/2.