Function library
Function blocks
3.5.22 Phase−analog converter (CONVPHA)
3−153
l
EDSVS9332P−EXT DE 2.0
3.5.22 Phase−analog converter (CONVPHA)
Three function blocks (CONVPHA1 ... CONVPHA3) are available.
Purpose
Conversion of a phase signal into an analog value.
CONVPHA1
CONVPHA1
CONVPHA1-OUT
C1002
± 199,99%
CONVPHA1-IN
C1001
2
C1000
1
Fig. 3−105 Function block CONVPHA1
Signal
Source Note
Name Type DIS DIS format CFG List
CONVPHA1−IN ph C1002 dec [inc] C1001 3
CONVPHA1−OUT a Limited to ±199.99 %
Function
l Conversion with adaptation using divisor.
l The conversion is performed according to the formula:
CONVPHA1–OUT + CONVPHA1–IN @
1
2
C1000
@
100%
16384
CONVPHA2
CONVPHA2
CONVPHA2-OUT
C1612
± 199,99%
CONVPHA2-IN
C1611
2
C1610
1
Fig. 3−106 Function block CONVPHA2
Signal
Source Note
Name Type DIS DIS format CFG List
CONVPHA2−IN ph C1612 dec [inc] C1611 3
CONVPHA2−OUT a Limited to ±199.99 %
Function
l Conversion with adaptation using divisor.
l The conversion is performed according to the formula:
CONVPHA2–OUT + CONVPHA2–IN @
1
2
C1610
@
100%
16384

Table of Contents