Residual hazards
Even if notes given are taken into consideraon and protecve measures are implemented,
the occurrence of residual risks cannot be fully prevented.
The user must take the residual hazards menoned into consideraon in the risk assessment
for his/her machine/system.
If the above is disregarded, this can lead to severe injuries to persons and damage to
property!
Product
Observe the warning labels on the product!
Dangerous electrical voltage:
Before working on the product, make sure there is no voltage applied to the power terminals!
Aer mains disconnecon, the power terminals will sll carry the hazardous electrical voltage
for the me given next to the symbol!
High leakage current:
Carry out xed installaon and PE connecon in compliance with:
EN 61800‑5‑1 / EN 60204‑1
Hot surface:
Use personal protecve equipment or wait unl the device has cooled down!
Protecon of persons
•
The power terminals may carry voltage in the switched-o state or when the motor is
stopped.
-
Before working, check whether all power terminals are deenergized.
•
Voltages may occur on the drive components (e.g. capacive, caused by inverter supply).
-
Careful earthing in the marked posions of the components must be carried out.
•
There is a risk of burns from hot surfaces.
-
Provide protecon against accidental contact.
-
Use personal protecve equipment or wait unl the device has cooled down.
-
Prevent contact with ammable substances.
•
There is a risk of injury due to rotang parts.
-
Before working on the drive system, ensure that the motor is at a standsll.
•
There is a risk of accidental start-up or electric shock.
Motor protecon
•
Installed temperature sensors are no full protecon for the machine.
-
If necessary, limit the maximum current. Parameterize the inverter so that it will be
switched o aer some seconds of operaon with I > I
rated
, especially if there is a risk
of blocking.
-
Integrated overload protecon does not prevent overloading under all condions.
•
The fuses are no motor protecon.
-
Use a current-dependent motor protecon switch.
-
Use the built-in temperature sensors.
Informaon on project planning
Safety instrucons
Residual hazards
17