Selecon tables
Torque characterisc during inverter operaon
Self-venlated geared motors Forced venlated geared motors
20 Hz to 120 Hz: Operaon at constant torque.
Below 20 Hz (n
21
): Derang without blower.
Below 5 Hz (n
22
): Vericaon of the applicaon by Lenze required.
5 Hz to 120 Hz: Operaon at constant torque.
Below 5 Hz (n
22
): Vericaon of the applicaon by Lenze required.
Notes on the selecon tables
The selecon tables represent the available combinaons of gearbox, number of stages, rao
and motor for the mounng posion M1. They only serve as a rough overview.
The following legend shows the layout of the selecon tables:
Example Explanaon
120 Hz: P
rated
= 0.55 kW Rated motor power at a rated frequency of 120 Hz
Inverter operaon Geared motor
5 Hz - - 20 Hz - 120 Hz (1:24)
n
22
M
22
n
21
M
2
n
2
M
2
c J i z m
rpm Nm rpm Nm rpm Nm kgcm² kg
55.8 2.9 231 3.9 1325 3.9 3.5 3.960 2.597 g500-H45 MFXMA 063-32 2 5.9
44.4 3.7 184 4.8 1053 4.8 4.8 4.602 3.267 g500-H140 MFXMA 063-32 2 9.0
43.2 3.8 179 5.0 1026 5.0 4.8 4.225 3.354 g500-H100 MFXMA 063-32 2 7.9
42.5 3.8 176 5.1 1008 5.1 2.8 3.869 3.413 g500-H45 MFXMA 063-32 2 5.9
Basic
weight
Number of gear
stages
Motor product name
Gearbox product name
Rao
Moment of inera without brake
Data at 120 Hz
n
2
= output speed - M
2
= output torque
c = the load capacity of the gearbox is the rao of the permissible rated torque of the gearbox to the
rated torque of the motor (converted to the output sha). c must always be greater than the applicaon
factor determined for the applicaon k
= >
´ ´ h
2,zul
1,N Getr
M
c k
M i
Data at 20 Hz
n
21
= output speed - M
2
= output torque
Data at 5 Hz
n
22
= output speed - M
22
= Output torque (forced venlated motors can deliver the torque M
2
over the enre adjustment range)
Technical data
Selecon tables