Owner's Manual Addendum Controlling the LXP-1 with Two-Way Communication
Two-way Control of Multiple LXP-1s
MRC
EXT
21
OUT IN
2121
LXP-1
LXP-1
can be patched to
LXP machines
controlling both
LXP-1s
Other MIDI
devices
T
H
R
U
Using two-way communication you can control two LXP-1s at once, one for
each input/output pair. If you have a high quality MIDI merger you can control
multiple LXP-1s on the same input/output pair. (Each LXP-1 and its
corresponding MRC machine must be assigned to a different MIDI channel.)
As long as the LXP-1 MIDI OUT is connected to the appropriate MRC IN you
can maintain two-way communication with it, even if other devices are daisy
chained to the MRC OUT. This is useful, for instance, when you want to
control the LXP-1 and one or more sound modules from a sequencer or
keyboard. (See illustration.)