3-8
A
DAILY OR EVERY 10 HOURS OF OPERATION
A1 - General inspection
CHECK
- Scrupulously inspect the machine and check that there are no fractured welds,
corrosion or structural damage, loose or missing nuts or bolts, hydraulic leaks,
damaged control cables or loose electrical connections.
- Check the absence of any damage in the lanyard anchorage points.
A2 - Function check
CHECK
Any malfunction on the part of the lifting platform must be discovered
every day before moving off in the lifting platform.
In the event of a malfunction being discovered, identify it and place the
lifting platform out of service.
Please refer to Chapter 2 for the markings for location of the controls.
The lifting platform must be set on a horizontal surface in a clear and unencumbered
area.
- CHECKING THE GROUND CONTROLS:
• Pull the red Emergency Stop knobs for the ground controls and the lifting
platform to the ON position.
• Set the ignition switch to Ground controls.
• Look at the lifting platform controls’ diagnostics display
> The “Bottom Station” display should be similar to the illustration in Fig.
A2-1 (ref 1).
Emergency Stop
• Push the red Emergency Stop knobs for the ground controls to the OFF position.
> Result: no function should be active.
• Pull the Emergency Stop knob to the ON position.
Lifting/lowering functions
• The buzzers for this machine and the standard buzzer all come from the same
central alarm. The buzzer emits a continuous noise. The descent alarm emits 60
beeps per minute. The alarm emits 180 beeps per minute when the machine is
tilted with the anti-pothole protection systems undeployed.
• Activate the lifting function.
> Result: the lifting platform should rise.
• Activate the descent function.
> Result: the lifting platform should descend. The descent alarm should flash
and sound when the lifting platform descends.
Emergency descent
• Activate the lifting function and raise the lifting platform approx. 60 cm.
• Pull the emergency descent control:
> Result: the lifting platform should descend. The descent alarm does not
sound.
• Set the ignition switch to Lifting Platform controls.
A2-1
1
647369 (01/03/2017)
78/100 SEC 2 / 120 SE 2