MAINTENANCE 999 LUFFING JIB OPERATOR MANUAL
6-14
Published 05-15-17, Control # 043-09
Adjustment
See Figure 6-9 for the following procedure.
Lower the boom onto blocking at ground level and adjust
each limit switch as follows:
1. Adjust spring tension so there is enough force to lift the
weight of the chain and rotate the actuating lever when
the weight is lifted.
2. Loosen the setscrew in the limit switch lever so the lever
is free to rotate.
3. Manually lift the weight to allow the actuating lever to
rotate upward.
4. Hold lever at Dimension A.
5. Hold the roller on the limit switch lever against the
actuating lever while performing step 6
6. Turn the limit switch shaft clockwise only enough to
“click” limit switch open and hold. Then securely tighten
the setscrew in the limit switch lever.
7. Test the limit switch for proper operation (see
Maintenance
); repeat the adjustment steps until the limit
switch operates properly.
Elbow with
Cable Gripper
Setscrew
Spring
Enclosure
Adjusting Screw
(spring tension)
Grease
Fitting
Dimension A
1.04 in (26 mm)
Actuating Lever
Limit Switch
Lever
Roller
Shaft
A1007
Cover
FIGURE 6-9
Left Hand Shown
Right Hand Opposite

Table of Contents

Other manuals for Manitowoc 999

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 999 and is the answer not in the manual?

Manitowoc 999 Specifications

General IconGeneral
BrandManitowoc
Model999
CategoryConstruction Equipment
LanguageEnglish

Related product manuals