Overload less than 25%
1 Lift Cylinder Inspect for leaking.
2
Turntable
Bearing
Check bolts for proper torque.
See topic in Swing section of
Service Manual.
3 Wire Rope Inspect all for damage.
See topic in Introduction section
of Service Manual.
Overload from 25% to 49%
1 Lift Cylinder Inspect for leaking.
2
Turntable
Bearing
Check bolts for proper torque.
See topic in Swing section of
Service Manual.
3 Wire Rope Inspect all for damage.
See topic in Introduction section
of Service Manual.
4 Hoist/Drums Inspect each for damage.
5 Hoist Brakes Brakes must hold rated line pull.
6
Bearing Main
Boom Pivot
Pin
Inspect for deformation, cracked welds.
7
Lift Cylinder-
lower mount
Inspect pin and welds.
8 Turntable Inspect for deformation, cracked welds.
9 Welds Inspect for cracks.
10 Paint
Inspect for cracked paint which could indicate twisted,
stretched, or compressed members.
Reference Only

Table of Contents

Other manuals for Manitowoc Grove RT540E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT540E and is the answer not in the manual?

Manitowoc Grove RT540E Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT540E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals