Published 01-15-2016, Control # 526-01 3-37
RT540E OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
RCL Setup Wizard
The RCL can be set graphically, or by direct number input or
rigging code. The rigging code is determined using the load
chart. This screen always appears with some rigging code
displayed, even if it does not match the actual crane
configuration.
The RCL is working correctly at this point if no error message
is showing. If any fault codes are present, the fault indicator
on the main CCS screen will be illuminated in red.
NOTE: If the RCL is not working correctly, do not start work
with the crane but notify Manitowoc Crane Care.
Set the Counterweight
When rigging is complete, the operator can toggle clockwise
to exit the outrigger position and move on to setting the
counterweight.
NOTE: Rough Terrain cranes have a fixed counterweight;
for them, the next function will be setting the boom.
Toggle clockwise and select the counterweight icon. The
available choices will assemble on the right of the screen.
NOTE: When the RCL override icon (above, the third icon
from the top on the status indicator bar on the right)
is flashing, it means that the override switch was
active at crane startup. In this case the override is
NOT active. To override the RCL, turn the switch
OFF for 1 second. Then, the override can be turned
ON again, and the RCL will be bypassed.
Reference Only