RT880E SERVICE MANUAL LUBRICATION
9
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
Turntable
30
Turntable Gear
Box
Figure 9-5
GL-5
Extended
Service Interval
Gear Lubricant
6829012964
5.7 qt
5.4 l
Check and fill every
50 hours
Drain and fill after
first 250 hours and
every 500 hours or
12 months thereafter.
Use Dipstick
31
Turntable Gear
and Drive Pinion
Figure 9-5
EP-OGL
Open Gear
Lubricant
6829102971
Coat all
teeth
500 hours or 6 months Spray on
32
Turntable
Bearing
Figure 9-5
EP-MPG
Extreme
Pressure
Multipurpose
Grease
6829003477
Until
grease
extrudes
the whole
circumfer-
ence of the
bearing
500 hours or 6 months
2 grease fittings at
the front of the
turntable.
NOTE: Rotate the turntable 90° and apply grease to fittings. Continue rotating 90° and grease the fittings until the whole
bearing is greased.
33
Turntable Lock
Pin
Not
Shown
EP-OGL
Open Gear
Lubricant
6829102971
Coat pin 500 hours or 6 months Spray on

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT880E and is the answer not in the manual?

Manitowoc Grove RT880E Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT880E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals