Part Number 000014141 Rev 11 12/23 49
Section 4 Maintenance
Step 4 Wait until the cycle is complete
(approximately 24 minutes). Then
disconnect power to the ice machine (and
dispenser when used).
n
Warning
Disconnect the electric power to the ice
machine at the electric service switch box.
Step 5 Remove parts for de‑scaling.
Notice
Refer to parts removal page 50.
Continue with Step 6 when the parts have
been removed.
Step 6 Mix a solution of de‑scaler
and lukewarm water. Depending upon
the amount of mineral buildup, a larger
quantity of solution may be required. Use
the ratio in the table below to mix enough
solution to thoroughly de‑scale all parts.
Solution
Type
Water Mixed With
De‑scaler 1 gal (4 L)
16 oz
(475 ml)
de‑scaler
Step 7 Use half of the de‑scaler & water
mixture to de‑scale all components. Use
caution not to expose electrical connectors
to liquid and soak parts for 5 minutes
(15 ‑ 20 minutes for heavily scaled parts).
The solution will foam when it contacts
lime scale and mineral deposits; once the
foaming stops, use a soft‑bristle nylon
brush, sponge or cloth (NOT a wire brush)
to carefully de‑scale the parts. When
de‑scaling is complete rinse all removed
components with clean water.
Step 8 While components are soaking,
use half of the solution to de‑scale all food
zone surfaces of the ice machine and bin
(or dispenser). Use a nylon brush or cloth
to thoroughly de‑scale the following ice
machine areas:
Side walls
Base (area above water trough)
Evaporator plastic parts ‑ including top,
bottom and sides
Bin or dispenser
Rinse all areas thoroughly with clean water.
SANITIZING PROCEDURE
Step 9 Mix a solution of sanitizer and
lukewarm water.
Solution
Type
Water Mixed With
Sanitizer 3 gal (12 L)
2 oz
(60 ml)
sanitizer
Step 10 Use half of the sanitizer/
water solution to sanitize all removed
components. Fill a spray bottle and use
caution not to expose electrical connectors
to liquid and liberally apply the solution to
all surfaces of the removed parts or soak
the removed parts in the sanitizer/water
solution. Do not rinse parts after sanitizing.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Indigo NXT IDT0300A and is the answer not in the manual?

Manitowoc Indigo NXT IDT0300A Specifications

General IconGeneral
BrandManitowoc
ModelIndigo NXT IDT0300A
CategoryIce Maker
LanguageEnglish

Related product manuals