Part Number 000014141 Rev 11 12/23 53
Section 4 Maintenance
Removal from Service/Winterization
GENERAL
Special precautions must be taken if the
ice machine is to be removed from service
for an extended period of time or exposed
to ambient temperatures of 32°F (0°C) or
below.
Notice
If water is allowed to remain in the ice
machine in freezing temperatures, severe
damage to some components could result.
Damage of this nature is not covered by
the warranty.
AIR-COOLED MODELS
1. Turn off the ice machine by pressing
the Power Button.
2. Turn off the water supply.
3. Remove the water from the water
trough.
4. Disconnect and drain the incoming ice‑
making water line at the rear of the ice
machine.
5. Energize the ice machine and wait
one minute for the water inlet valve
to open ‑ or ‑ Energize all relays in the
touchscreen service menu.
6. Blow compressed air in both the
incoming water and the drain openings
in the rear of the ice machine until no
more water comes out of the water
inlet lines or the drain.
7. Disconnect the electric power at the
circuit breaker or the electric service
switch.
8. Make sure water is not trapped in
any of the water lines, drain lines,
distribution tubes, etc.
WATER-COOLED MODELS ONLY
1. Perform steps 1‑6 under “Air‑Cooled
Ice Machines”.
2. Disconnect the incoming water and
drain line from the water‑cooled
condenser.
3. Start the ice making cycle by pressing
the Power button and wait for the
freeze cycle. The increasing refrigerant
pressure will open the water
regulating valve.
4. Blow compressed air through the
condenser until no water remains.
5. Turn off ice machine by pressing the
Power button and then disconnecting
power to the ice machine.
6. Perform a lock out tag out procedure.