National Crane Published 9-26-2018 Control # 646-02 7-9
NTC55 OPERATOR MANUAL RATED CAPACITY LIMITER
If any of the four Outrigger Length Monitoring Sensors are
out of range or not functioning properly, that beam will show
at midspan position and will be colored in red (Figure 7-7).
Screen 6-1
When using the personnel basket, Fully Extended outriggers
are required
. Select OK after machine is in Fully Extended as
displayed on Screen 6-1. When within Fully Extended range,
the left-hand O/R graphic changes from GRAY to BLUE.
If user attempts to select OK before Fully Extended condition
is met, the OK button will color RED when depressed and the
user can override the setup using the arrow keys as
displayed on Screen 6-2.
Screen 6-2
If the user selects a setup configuration different than the one
selected by the RCL, the O/R override icon will be displayed
on screen 9 and on the RCL Operating Mode Screen shown
on page 7-11.
When using the jib, Fully Extended, 75% Extended, or 50%
Extended outriggers are required
. Select OK after machine
is in Fully Extended or 50% Extended. When within Fully
Extended, 75% Extended, or 50% Extended range, the
appropriate left-hand O/R graphic changes from GRAY to
BLUE.
Screen 6-3
If user attempts to select OK before Fully Extended or 50%
Extended condition is met, the OK button will color RED
when depressed and the user can override the setup using
the arrow keys.
If the user selects a setup configuration different than the one
selected by the RCL, the O/R override icon will be displayed
on Confirmation Screen (screen 9 on page 7-10) and on the
RCL Operating Screen shown on page 7-11.
if 75% Extended outrigger position option is enabled and not
the jib or basket are selected, then the screen will look as it
does below as displayed on Screen 6-4.
FIGURE 7-7
7521-10c
Error with
one sensor