RATED CAPACITY LIMITER NTC55 OPERATOR MANUAL
7-10 Published 9-26-2018 Control # 646-02
Screen 6-4
Select OK after machine is in outrigger setup configuration
w/o jib or basket with 75% extended.
HOIST & REEVING CONFIGURATION
Screen 7
Select 1 to show the Main Hoist enabled; select 2 to show
the auxiliary hoist enabled.
The hoist that is being used will be displayed as in Screen 7
and on the RCL Operating Mode Screen in blue (page 7-4).
Screen 8
If selected 1 (Main Hoist) on Screen 7; use the up and down
arrows to change reeving from 1 part line up to 10 parts line
on Screen 8.
Confirmation
After the RCL crane configuration setup is complete,
confirmation Screen 9 is displayed. Check the configuration
and select OK if the configuration is correct. This verifies the
lift configuration of the crane.
If the confirmation Screen 9 is not correct, use the back
arrow key to go back to Screen 8 and correct the
configuration.
If the machine is shut down and restarted again within 2
hours, the operator can select OK at Screen 9. Selecting OK
will automatically return the RCL to the configuration used at
shutdown. Re-configuration of the RCL will not be required.
Screen 9
OPERATING MODE
After the RCL is setup is complete the RCL Operating Mode
screen is displayed.
The key functions at the bottom of the RCL Operating Mode
screen are:
- - MAIN - Pressing this key returns to the
MAIN Menu screen.
- - Horn Silence indicates the RCL warning
horn is temporarily disabled for 15 seconds. The
horn silence button icon will be shaded when active.
- - Reeving selecting screen; pressing this
button returns to the reeving configuration screen
for number of parts of line selection.
- - Wrench; pressing this button returns to the
diagnostics screen.
- LIMIT - Pressing enables the RCL Limits Menu
screen and WADS options main menu.
- TARE - Pressing will enable/disable Tare or
zeros out the current load indicated on the screen to
show the active weight of the load only. TARE button
icon will flash BLUE when active.
- - Delete - Pressing this key deletes the
current setting or value.