10
5.3 TROUBLESHOOTING  ROPE NOT RETRACTING
ROPE WILL NOT RETRACT OR RETRACTS SLOWLY
POSSIBLE CAUSES
1) The spin axles are not wound tight enough.
2) The spin axles are defective.
SOLUTION
1) Remove the middle shrouds as outlined in Section 6.2, and rewind the spin axles (Figure A). The right side spin axle should be wound clockwise 2.5 - 3
revolutions, the left side spin axle should be wound counter clockwise 2.5 - 3 revolutions.
2) If the rope still will not retract, replace the spin axles.
FIGURE A