EasyManuals Logo
Home>Metrohm>Measuring Instruments>PGSTAT302N

Metrohm PGSTAT302N User Manual

Metrohm PGSTAT302N
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Insert new module for the Autolab 8-Series
4 | Page
2 Overview table loose modules
Module
Items
Quantity
Required software
PGSTAT100N
compatible?
BA
Module label
SMB-Coax cable
SMB-Coax cable copper
SMB-Coax Banana cable
Alligator clip
Warning on PGSTAT100N
1
3
1
1
1
1
GPES 4.9.7 or higher
Nova 1.2 or higher
YES, with adjusted DIFFAMP
FRA2
Module label
SMB-Coax cable
CD with calibration file
2
3
1
FRA 2.4 or higher
Nova 1.2 of higher
YES
FRA32M
Module label
SMB-Coax cable
1
3
Not supported in FRA
Nova 1.8 or higher
YES
pX1000
Module label
Cover for front connector
Lemo to banana cable
Analog bus connector
Warning on PGSTAT100N
1
1
2
1
1
Not supported in GPES
Nova 1.4 or higher
NO
EQCM
Module label
Oscillator box
DB9 Oscillator connection cable
Crystal 6 MHz Au/TiO
2
polished
EQCM cell
Au counter electrode
Reference electrode
Ag/AgCl, 3M KCl
Driving force adjustment tool
Spare O-ring Reference electrode
Spare O-ring Counter electrode
Spare O-ring Viton Crystal
Spare O-ring Cell cover
2.5 mm hex driver
Spare EQCM cell screw
Warning on PGSTAT100N
1
1
1
2
1
1
1
1
1
1
4
1
1
3
1
Not supported in GPES
Nova 1.4 or higher
YES
ECD
Module label
SMB-Coax cable
1
1
GPES 4.5 or higher
Nova 1.3 or higher
YES
MUX
Module label
Digital MUX cable
Warning on PGSTAT100N
1
1
1
GPES 4.7 or higher
FRA 4.7 or higher
Nova 1.5 or higher
NO
SCAN250
Module label
SCAN250-ADC trigger cable old
SCAN250-ADC trigger cable new
1
1
1
GPES 4.9.7 or higher
Nova 1.2 or higher
YES
ADC10M
Module label
ADC10M-SCAN trigger cable old
ADC10M-SCAN trigger cable new
Ferrite bead
1
1
1
1
Not supported in GPES
Nova 1.2 or higher
YES
ECN
Module label
Analog bus connector
Special ECN cable
Warning on PGSTAT100N
1
1
1
1
GPES 4.8 or higher
FRA 4.9.5 or higher
Nova 1.5 or higher
NO
FI20
Module label 1
GPES 4.5 or higher
Nova 1.5 or higher
YES
Table 1 Module compatibility table
Table 1 provides the overview for loose modules available for 8-Series Autolab
instruments, the part list for each module and the software and hardware requirements
or restrictions.