Page #88 background image
Cleaning and care
88
Cleaning the spray arms
Particles of food can get stuck in the
spray arm jets and bearings. The spray
arms should therefore be inspected reg-
ularly (approx. every 2–4months).
Never run a wash program without
using the spray arms.
Damage due to soiling entering
the circulation system.
Without filters, soiling can enter the
circulation system and cause a
blockage.
Do not run a wash program without
the lower spray arm or without the fil-
ters.
When cleaning the filters and spray
arms, make sure that coarse soiling
cannot get into the circulation sys-
tem.
Turn off the dishwasher.
Removing the cutlery tray (if present)
In order to be able to remove the upper
spray arm, you first have to remove the
cutlery tray (if present).
Pull out the cutlery tray.
Press the rail safety clips on both
sides of the cutlery tray together
and remove the safety clips at the
same time.
Take out the cutlery tray completely.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Miele G 7591 and is the answer not in the manual?

Miele G 7591 Specifications

General IconGeneral
TypeBuilt-in
Built-in displayYes
Inlet hose length1.5 m
Outlet hose length1.5 m
Delayed start timerYes
Delay start (max)24 h
AquaStop functionYes
Child lockYes
AC input frequency50 Hz
Washing programsAuto, Quick
Width598 mm

Related product manuals