Adding and dispensing process chemicals
52
Refilling liquid
process chemi-
cals
Open the drawer of the side unit.
Remove the liquid process chemical container (blue marking) and
place it on the open cabinet door or on a surface which is robust
and easy to clean.
Take the lid off the canister and remove the suction wand. Place the
suction wand on the open wash cabinet door.
Replace the empty container with a full one.
Push the suction wand into the opening of the container and secure
the lid. Observe the color coding.
Feed the suction wand into the container until it reaches the bot-
tom.
Wipe up any spilled process chemical thoroughly.
Place the container back in the drawer in the side cabinet.
Close the drawer. Ensure that the dispensing tubes and cords are
not kinked or trapped.
After that, the dispensing system must be primed (see “Settings /
Priming DOS”).