The display shows a fault message
Display message Possible cause Solution*
q
Drainage fault
The drain is blocked.
The drain hose is too
high.
Clean the drain filter and
the drain pump.
The maximum drain
pump height is 3 ft (1 m).
p
Water intake
fault
The water intake/inlet is
blocked.
Possible fault
the water valve is
closed.
the inlet hose is kinked.
the filters are blocked.
ä
Drainage lighting
fault
The drum light is not
locked in position.
Check that the drum light is
correctly fitted.
,
Technical
fault
There is a fault. Start the program again.
If the fault message
appears again call Miele’s
Technical Service
Department.
* To cancel an error message, press OK.
Frequently asked questions
31

Other manuals for Miele PW 5065

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele PW 5065 and is the answer not in the manual?

Miele PW 5065 Specifications

General IconGeneral
Load capacity6.5 kg
Energy efficiency classA+++
TypeFront-loading
Electrical connection220-240V, 50Hz
ControlsElectronic
Heater rating2.1 kW