2. DESIGN
2
17
2.4 Layout Design within Enclosure
2.4.1 Location Environment
Avoid locating the motion controller system in environments subject to:
(1) Ambient temperature outside the range 0
°
C to 55
°
C
(2) Ambient humidity outside the range 10% to 90% RH
(3) Condensation resulting from sudden temperature changes
(4) Corrosive or inflammable gas
(5) Large amounts of conducting dust or iron filings, oil mist, salt, organic solvents
(6) Direct sunlight
(7) Strong electrical or magnetic fields
(8) Direct vibrations or shocks on the unit.
CAUTION
The storage conditions are listed in the table below.
Environment Conditions
Ambient temperature 0
C
to 55
C
Ambient humidity 10% to 90% RH
Atmosphere
No condensation resulting from sudden temperature changes
No corrosive or inflammable gas
Low levels of conducting dust or iron filings, oil mist, salt, organic solvents
Not subject to direct sunlight
No strong electrical or magnetic fields
No direct vibrations or shocks on the equipment.

Table of Contents

Other manuals for Mitsubishi Electric A172SHCPUN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric A172SHCPUN and is the answer not in the manual?

Mitsubishi Electric A172SHCPUN Specifications

General IconGeneral
BrandMitsubishi Electric
ModelA172SHCPUN
CategoryControl Unit
LanguageEnglish

Related product manuals