M-Series & P-Series Indoor Unit Function Codes
Mode # Indoor Unit Compatibility Function Setting # Settings
1 All Power Failure Auto Recovery
1 Not available (OFF)
2 *1-1 Available (ON ) approximately 4 minute delay
2 All Indoor Temperature Detection
1 Average data from all unit
2 Return air
3 *2-1 Remote Controller
3 All Lossnay Connectivity
1 Not supported
2 IDU does not intake OA through Lossnay
3 IDU does intake OA through Lossnay
4 All Power Supply Voltage
1 230 volt
2 208 volt
5 PEAD Auto Mode
1 Energy saving cycle automatically enabled
2 Energy saving cycle automatically disabled
7 All Filter Sign
1 100 hours
2 2500 hours
3 No filter sign indicator
8
*D
SLZ/PLA
PCA/PKA
Air Flow (Fan Speed)
1 Quiet
2 Standard
3 High ceiling
8
*D
SEZ/SVZ/PEAD/PVA Static Settings See "Static Pressure Settings" on page 12.
9 PLA Number of Air Outlets
1 4 directions or all 4
2 3 directions or just 3
3 2 directions or just 2
10
*D
PLA
PCA
High Performance Filter Also Static
Settings
1 Not supported
2 Supported
10
*D
SEZ/SVZ/PEAD/PVA Static Settings See "Static Pressure Settings" on page 12.
11
*D
PLA Horizontal Vane Setting
1 Downward setting (vanes angle setup 3)
2 Middle setting (vanes angle setup 1)
Draft less setting (vanes angle setup 2) *11
11
*D
SLZ
PCA
Horizontal Vane Setting
1 No setting
2 Draft less setting (vane angle setup 1)
Downward setting (vanes angle setup 2)
11
*D
SVZ/PEAD/PVA Heater Control (Used with Mode 23)
1 No heater present
2 Heater available
12
SLZ-KF/
PLA-A__EA7
3-D i-See Sensor Positioning
*12-1 *12-2
1 Position 1
2 Position 2
3 Position 3
13 SVZ/PVA Optional Humidifier
1 Not supported
2 Supported
14
PLA
PCA/PKA
Vane Differential Setting in Heating Mode
(Cold Wind Prevention)
1 75-82 °F TH5
2 82-90 °F TH5
3 90-100 °F TH5
15
SLZ/PLA
SEZ/SVZ/PEAD
PCA/PKA
Frost Prevention Temp
1 (2 °C) 36 °F
2 (3 °C) 37 °F
Note: Default settings for Function Codes 1-28 are automatically determined by the HVAC equipment. It may take up to 40 seconds to
enter setup and 30 seconds to exit setup. Please refer to the indoor unit manual for unit specific function codes and the description of their
values. A summary is shown in the following tables.
33-00446EFS_B.indd 8 10/17/2019 3:09:00 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric RedLINK MIFH2 and is the answer not in the manual?

Mitsubishi Electric RedLINK MIFH2 Specifications

General IconGeneral
BrandMitsubishi Electric
ModelRedLINK MIFH2
CategoryRemote Control
LanguageEnglish

Related product manuals