6.
PROGRAMMING
/MELSEC-A
6.1.2
Nota on programming
/-
(1
)
Initial
program
The following program steps should be used with the AD71.
-4
M9038
XA (battery error)
n
Ii
M9006
(ACPU battery error)
I
I
W
(ACPU RUN)
-it
M9039
Interlock
IU
XI
W
b
Provide stan interlock.
AD71 ready
Usable for stop, etc.
xB
Error detection
tb
<b
I
0
sequence
‘Resetting the ACPU while the AD71
is
“bury”
may
cause
it
to
flag an error, to
guard against this use
the
above
sequence.
‘Resets A071 error
1
scan
after CPU RUN.
Bettew error
PC resdv
Fig.
6.2
Initial
Program
(2)
PC
ready reset
Where necessary, the
PC
ready signal should be disabled when
an error
is
detected.
(3)
Zeroing
The system should
be
zeroed before positioning
is
started and
when
a
zeroing request
is
received from the AD71.
(4)
Zeroing actuator
Ensure that the zeroing actuator
is
serviceable and reliable.
Failure to receive an input from this switch will allow the zeroing
routine to maintain the drive signal.
(5)
Overrun precautions
1
,
The upper and lower stroke limits will only be operable
if
the
AD71
is
functioning normally. Upper and lower limit switches
should be hard wired into the system.