Section 6
Unit will not dispense drinks and\or gas only
Does the display
state “Fault type: -A
Consult Manual”?
Carbonatorllhas
timed out. Turn
unitpoweroand
back on again.
Check the
mains power
supply to the
unit is switched
on.
Check the 10A
fuse in the
mains plug is
ok.
Check the
cable and\or
connections
from the PCB
to the display
are ok.
1. Loose internal
wiring
connection.
2. Faulty display
3. Faulty PCB.
1. Faulty display.
2. Faulty PCB.
3. Software glitch
Try turning unit
oandthenon
again.
Check that the
mains water supply
is present and is of
an adequate
pressure.
Check the following:-
1. Faulty or seized carbonator
pump.
2. Faulty carbonator pump motor.
3. Faulty solenoid valve
4. Loose wiring connections to
above components.
5. Blocked carbonator bowl inlet
Orice.
6. Product coils frozen. (refer to
refrigeration chart)
7. Faulty PCB.
Restore
water supply
and reset.
Check Co2 is not above
80PSI.
Adjust Co2 pressure to
80 PSI. Exhaust over
pressure by pulling
pressure relieve valve
on Carb bowl.
Is the display panel
illuminated?
No
Yes
Yes
No
No
Yes
Yes
No
No
Yes
Faulty cable or
cable
connectors.
Replace \repair
Switch the unit
on at the mains
plug.
Replace the
fuse & switch
the unit on.
Does the display
state “Ready to
dispense”?
NoYes
No
NoYes
No
1. No Co2 supply to
Unit. (Syrup
dispense only)
2. Faulty membrane
switch.
3. Faulty membrane
switch connection to
display PCB.
4. Product coils frozen
(refer to
refrigeration chart)
5. Faulty dispense valve
solenoid.
6. Loose wiring
connections to
above components.
7. Faulty or loose
connection cable
between display &
PCB
8. Faulty PCB.
No
Check carbonator
motor is not disabled.
Yes