61
Section 6
ALBI AQUA – Fault nding
Section6oftheInstallationManualcontainsowdiagramsforidentifyingand
correcting faults within the unit.
WhilstthesectioncontainssomeinformationspecictothepostmixALBI
variants, most of the ALBI AQUA fault conditions are also described, except the
condition described below...
Carbonatorbowllevelsensorcallsforrell
Carbonator pump cuts out after 45 seconds
RedLEDashingatfrontofunit
Stopdispensingdrinksandswitchopoweratmains
Waterowtocarbpumpiseithertooslow
or has stopped
Investigateandcorrectthecauseofinsucient
waterow
Switch on power at mains. Flashing light is cleared
andcarbbowlllswithin45seconds
Continue dispensing drinks
Carbonator pump cuts out within 45 seconds
NoredLEDashingatfrontofunit
Continue dispensing drinks
Carbonator pump starts
Switch on power at mains. Carbonator pump again cuts out
after 45 seconds. Flashing LED returns