EASY MENU DRIVEN PROGRAM MODE
DEALER PROGRAM (PRELIMINARY INFORMATION)
The Master Security Code is printed on the label affixed to the label stuck to the top of the two rectangular relays on the right side of
the motherboard PCB. Use this code to enter the Easy Menu Driven Program Mode to program a custom Dealer Keypad Program
Code. Record the number, then remove the code label to prevent unauthorized access to the panel (keep the code label in a safe
place). If you forget your custom Dealer Keypad Program Code, use the Master Security Code to enter programming.
 After entering codes or data, press the save ENTER button. Data will not be stored into memory unless ENTER is pressed.
 If the keypad is in Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.
 Silence the sounder by pressing the "Acknowledge"
D button to continue, or by pressing C to exit.
 A panel that has been COLD STARTED (address location 8179) performs identically to a new panel and displays system trouble
"
ERRORcheck Required".
 When programming more than 2 areas, Direct Address Programming Mode must be used to complete the program.
NEW PANELS: The custom default program may be created for new panels only. Once the panel has been programmed by any
means, the number of areas, number of zones, Fire zones, entry/exit zones and interior zones will be suppressed and cannot be
changed. Should it be necessary to create a new custom default program, perform as follows: From the Dealer Program Mode,
press the RESET button to enter the Direct Address Program Mode. Then access Location 8177 "Clear Program" and press the
ENTER button and start over.
ACCESSING DEALER PROGRAM MODE
CUSTOMIZING A DEFAULT PROGRAM
For new panels, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for:
This procedure will automatically set up system keypads, EZM's, wireless transmitters, etc. After your basic default program has
been loaded, you may alter it as necessary in the Direct Address Program Mode.
 Total Number of Fire Zones in Area 1
 Total Number of Burg Zones in Area 2
 Local or Central Station Reporting
System
 Exit/Entry Zones in Areas 2-8
 Interior Zones
 24 Hour Zones in Area 2 and Up
 Chime Zones in Area 2 and Up
 Chime 2 Zones in Area 2 and Up
 Exit/Entry 2 Zones in Area 2 and Up
 50mS Loop Response Zones (Note: 750mS is
required for Loop Response time in UL installations)

Burg Module PGM1 Output Activated on
Alarm Zones
 Sensor Watch Zones
 Keypad Sounder On Alarm Zones
 Auto Bypass Re-entry Zones
 Enable No EOLR Zones
 Enable Telco Line Fault Test?
 Enable Burg Bell Chirp on Keyfob?
 Number of Fire Keypads in Area 1
 Number of Keypads in Area 2
 Central Station Receiver 1 Telephone
Number
 Central Station Receiver 1 Account
Number
 Central Station Receiver 1 Format
 Enter User Codes
 RF Transmitter/SLC Points
 Keyfob Transmitters as Arm/Disarm &
Control Devices
 Enter Zone Descriptions
 Enter Date
 Enter Time
 Enter a Dealer Keypad Program Code
KEYPAD #1: Keypad Programming can ONLY be made using a GEMC-FK1 Fire keypad addressed as keypad #1 and wired
to the Fire bus (not the Burg bus). For UL installations, keypad programming is used for the initial set-up/test only. After key-
pad programming, the system must first be uploaded to the PCD-Windows Quickloader software; the account type must be
selected (either UL Commercial Fire or UL Commercial Fire and Burglary), and after error checking is completed, the program
must then be downloaded back to the panel. For Burglary-only systems, a GEMC-BK1 Burglary keypad may be used.
1. Press EEEEEE U to unlock the keypad.
2. Press R until "CF Dealer Prog Mode" appears on the keypad display.
3. Press
U to enter Dealer Program Mode.
4. Press
CC to exit Dealer Program Mode when finished.
MASTER SECURITY CODE
# # # # # #
Refer to WI1653
(Label affixed to the top of the
two rectangular relays on the
right side of the motherboard
PCB).
(Master Security Code)

Table of Contents

Other manuals for NAPCO GEMINI GEMC-128

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO GEMINI GEMC-128 and is the answer not in the manual?

NAPCO GEMINI GEMC-128 Specifications

General IconGeneral
BrandNAPCO
ModelGEMINI GEMC-128
CategoryControl Panel
LanguageEnglish

Related product manuals