© National Instruments Corporation 5-3 NI-488.2 User Manual
Communication Errors
The following sections describe communication errors you might
encounter in your application.
Repeat Addressing
Devices adhering to the IEEE 488.2 standard should remain in their current
state until specific commands are sent across the GPIB to change their
state. However, some devices require GPIB addressing before any GPIB
activity. Therefore, you might need to configure your NI-488.2 driver to
perform repeat addressing if your device does not remain in its currently
addressed state. You can either reconfigure from your application using
ibconfig, or reconfigure using Measurement & Automation Explorer.
Note National Instruments recommends using ibconfig to modify the configuration.
If your application uses
ibconfig, it works properly regardless of the
previous configuration. For more information about
ibconfig, refer to
the description of
ibconfig in the NI-488.2 online help. For instructions
on accessing the online help, refer to the Using the NI-488.2
Documentation section in About This Manual.
Termination Method
You should be aware of the data termination method that your device uses.
By default, your NI-488.2 software is configured to send EOI on writes and
terminate reads on EOI or a specific byte count. If you send a command
string to your device and it does not respond, it might not be recognizing
the end of the command. In that case, you need to send a termination
message, such as <
CR> <LF>, after a write command, as follows:
ibwrt(dev,"COMMAND\x0D\x0A",9);
Other Errors
If you experience other errors in your application, refer to the NI-488.2
online help. It includes extensive troubleshooting information and the
answers to frequently asked questions. For instructions on accessing the
online help, refer to the Using the NI-488.2 Documentation section in
About This Manual.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments NI-488.2 NI-488.2 and is the answer not in the manual?

National Instruments NI-488.2 NI-488.2 Specifications

General IconGeneral
BrandNational Instruments
ModelNI-488.2 NI-488.2
CategorySoftware
LanguageEnglish