Rebecca WiseSep 10, 2025
How to fix clogging in Netafim NETAJET 4G's needle valve?
- JJacqueline ObrienSep 10, 2025
If clogging is present in the needle valve of your Netafim Industrial Equipment, thoroughly clean the needle valve.
How to fix clogging in Netafim NETAJET 4G's needle valve?
If clogging is present in the needle valve of your Netafim Industrial Equipment, thoroughly clean the needle valve.
What to do if Netafim Industrial Equipment controller warns about low EC?
If the Netafim Industrial Equipment controller is showing a low EC warning, check and calibrate the EC and pH sensors.
What to do if Netafim NETAJET 4G controller warns about high pH?
If the Netafim Industrial Equipment controller is showing a high pH warning, check and calibrate the EC and pH sensors.
What to do if Netafim NETAJET 4G controller warns about low fertilizer/acid flow rate?
If the Netafim Industrial Equipment controller is showing a low fertilizer/acid flow rate warning, check and calibrate the EC and pH sensors.
What to do if Netafim Industrial Equipment rotameter reading shows low fertilizer/acid flow rate?
If the Netafim Industrial Equipment rotameter reading indicates a low fertilizer/acid flow rate, check and calibrate the EC and pH sensors.
What to do if Netafim NETAJET 4G does not function at all?
If the NetaJet™ 4G does not function at all, have a qualified electrician check the overload protection breaker.
What to do if Netafim Industrial Equipment Venturi has internal deformation?
If the Venturi in your Netafim Industrial Equipment has internal deformation, replace the Venturi.
What to do if there is no suction from the Netafim NETAJET 4G dosing valve?
If there is no suction from the dosing valve in your Netafim Industrial Equipment, disconnect the dosing valve and check it for clogging.
What to do if Netafim NETAJET 4G needle valve has internal deformation?
If there is internal deformation present in the needle valve of your Netafim Industrial Equipment, replace the needle valve.
What to do if Netafim NETAJET 4G's original hydraulic conditions are still not restored after bleeding?
If the original hydraulic conditions in your Netafim Industrial Equipment are still not restored, check the dosing booster's impeller chamber for clogging.
Brand | Netafim |
---|---|
Model | NETAJET 4G |
Category | Industrial Equipment |
Language | English |
Details on the Bypass system for pressurized-line water source.
Details on the Bypass system for storage-tank water source.
Details on the high-flow bypass system for pressurized-line water source.
Actions for addressing issues affecting multiple dosing channels.
Troubleshooting steps for problems with individual dosing channels.
Steps to take when the NetaJet™ 4G is not actively operating.
Troubleshooting when the entire NetaJet™ 4G system is non-operational.
Causes and solutions for vibrations occurring during NetaJet™ 4G operation.
Method for calculating necessary suction reduction for accurate dosing.
Procedure for simulating dosing performance using a test bucket.
Final calibration steps performed during active irrigation.