NETAJET 4G HYDRAULIC CONDITION CHECKLIST
Testing date
Inlet PRV pressure
bar / PSI
Lower manifold pressure
bar / PSI
Outlet PSV pressure
bar / PSI
Main line pressure
bar / PSI
Main line flow
m
3
/h / GPM
Q suction
l/h / GPM
Source water EC
Source water pH
Dripperline water EC
Dripperline water pH
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
Reference data
Serial number
Project name
Technician name
Installation date
Notes
Check the inlet, lower manifold, outlet and main line
pressure gauges and the main line flow meter and make
sure all the hydraulic conditions are in range according
to the following table.
Mode
Inlet PRV
pressure
bar (PSI)
Lower manifold
pressure
bar (PSI)
Outlet PSV
pressure
bar (PSI)
Main line
pressure
bar (PSI)
Main line
flow
m
3
/h (GPM)
BP PL
3.5-4.0
(50.7-58.0)
0-+0.5
(0 -7.2)
4.0
(58.0)
Standard:
2.5-5.8 (36.5-84.0)
High pressure:
5.8-7.5 (84.0-108.5)
20-120 (90-500)*
Octa
IL PL Up to 20 (90)
High-flow 80-400 (350-1760)*
BP ST
- 0-+0.5 (0-7.2)
15-100 (66- 440)*
IL ST Up to 20 (90)
*In all bypass modes flow limitation depends on the fertilizer injection rate and the size of the venturis.