VBA23001-R.3762.A
- A110 D90 -
Measurement of Consumption current value
When this camera is used for measuring the consumption current value, connect the battery tool (J61213), and
turn the change-SW to OFF. Then make measurements based on the following.
7.8V 0.3Ω
Test item Standard Test condition
Main SW /
OFF
All operational buttons are NOT pushed. ref. above.
AF50/1.4D
EV12
Main SW /
ON (Half-release timer OFF)
Main SW /
ON (Half-release timer ON)
Main SW /
ON (Illumination ON)
Main SW /
ON (TFT ON)
   
Main SW / ON (Operating consumption current)
Inspection standards
Turn change-SW to OFF.
Caution:
When the consumption current value is measured, backup battery must be fully charged.
400mA or less
200mA or less
250μA or less
250μA or less
250mA or less
4A or less
INC