20
Date/time
It is important to set date and time correctly. It makes it easier to trace potential faults when an error is being reported. When logging
data, it is important to be able to follow the history. You set the time in the settings menu.
> Date/time
Week programs
You can program the ventilation unit to run in accordance with specific settings at fixed times during the day and week via a week pro-
gram.
> Week program
> Unit type Description: Shows what type of ventilation unit it is.
> Software version Description: Shows the software version of the ventilation unit.
> Panel software Description: Shows the software version of the control panel.
> Year Description: Press “Year” on the panel and select the current year.
> Month Description: Press “Month” on the panel and select the current month.
> Day Description: Press “Day” on the panel and select the current day of the week.
> Hour Description: Press “Hour” on the panel and select the current hour of the day.
> Minute Description: Press “Minute” on the panel and select the current minute.
On the main screen of the control panel, in the top right corner, the Week program icon will be displayed when active.
> Select Week program Settings:
Standard setting:
Description:
Off / 1 / 2 / 3
Off
The control allows you to set 3 programs for different situa-
tions e.g.:
Normal operation
Holliday operation
> Edit program Description: The selected Week program is now active and can be edited.
> Monday Settings: Here weekday is selected.
>Function 1 Settings: Here you select the function you want to edit.
> Start time Settings:
Standard setting:
Description:
Hours and minutes
6:00
Set the time for the program to start. The program will run with
the set values until the next change in the Week program.
> Ventilation Settings:
Standard setting:
Description:
Level 1 / Level 2 / Level 3 / Level 4 / Off
Level 3
Select the desired fan speed level here.
> Temperature Settings:
Standard setting:
Description:
5  40 °C
22 °C
Set the desired room temperature here.
> Copy for next day Description: Once the values for the Monday program have been set, it is
possible to copy these to the next day.
The same settings are made for
all functions.
> Reset program Settings: You can reset the program by selecting the “Approve” icon.