Using 5.0W Modules on Ports 49, 50, 55, 56 in SN2410M/SN2410bM
Supported Passive Cables in SN2010bM
For server ports:
25GbE cables (all ports can be used):
1m-1.5m: any DAC
2m: MCP2M00-A002E30N
2.5m: MCP2M00-A02AE26N
3m: MCP2M00-A003E26N
10GbE cables (all ports can be used):
0.5m to 5m: any DAC
For IPL ports (SN2010 to SN2010 connection):
40/100GbE cables (all ports can be used):
No limitations
25GbE cables (only ports 3, 6, 9, 12, 15, 18 can be used)
Up to 2m: any DAC
10GbE cables (all ports can be used):
0.5m to 5m: any DAC
For connections with other switches:
AOCs/Transceivers only
Supported 25GbE and 40/100GbE Cables on IPL Ports (SN2010 to SN2010 Connection)
Speed
Ethernet speed must be set manually. The system’s ports can be manually configured to run at
speeds ranging from 10GbE to 100GbE (for more details, seeSpecifications). To change the port
speed configuration, use the command “speed” under interface configuration mode. Refer to the
NVIDIAOnyx (MLNX-OS) User Manualfor instructions on port speed re-configuration.