174
UNIX Application Example Section 7-6
2. If the peripheral servicing time setting in the PC Setup is increased, FTP
files will be transferred faster.
7-6 UNIX Application Example
The following procedure provides an example of FTP operations from a UNIX
workstation. In this example, the following assumptions are made.
The IP address of the Ethernet Unit is registered in /etc/hosts on the
workstation as “cs1”.
The default FTP login name is being used (CONFIDENTIAL).
A processing results data file called RESULT.IOM already exists on the
Memory Card in the CPU Unit.
A processing instructions data file called PLAN.IOM already exists on the
workstation.
The following procedure transfers the processing results file RESULT.IOM
from the Memory Card in the CPU Unit to the workstation and then the pro-
cessing instructions file PLAN.IOM is transferred from the workstation to the
Memory Card in the CPU Unit.
Underlined text is keyed in from the FTP client. The workstation prompt is indi-
cated as $ and the cursor is indicated as .
1,2,3... 1. Start FTP and connect to the Ethernet Unit.
2. Enter the login name.
3. Make sure the Memory Card is inserted. The MEMCARD directory will be
displayed if there is a Memory Card in the CPU Unit.
FTP started.
Login name
Used to check for Memory Card.