STARTER
WARNING
Accidental or remote starting can
cause severe personal injury or death. Before
removing an access door or belt guard, discon-
nect the negative (−) cable at the battery to pre-
vent the engine from starting.
The starter motor is bolted to the flywheel housing
(Figure 6-4). See the Engine Workshop Manual
(Table 6-1) for service or replacement. Parts are
available for rebuilding the starter. Torque the
mounting bolts to 29 lb-ft (39 N-m).
GROUND ISOLATION RELAY K9
When required, the genset is equipped with isola-
tion relay K9 (Figure 6-4) to isolate the negative (−)
battery terminal from the vessel grounding system
while the genset is running. (The engine block is
connected to battery negative [−] during starting.)
Replace the relay if its contacts do not close when
battery voltage is applied to the coil terminals.
BATTERY CHARGING ALTERNATOR
See Page 4-13 to adjust or replace the alternator V-
Belt (Figure 6-4). See the Engine Workshop Manual
(Table 6-1) for service or replacement.
RAW WATER PUMP
See Page 4-12 to replace the impeller. Kits are
available for servicing the raw water pump. Follow
the instructions in the kit.
RELAY
K9
STARTER MOTOR
(OTHER SIDE ON MDKBP, MDKBR, MDKBS)
BATTERY
CHARGING
ALTERNATOR
FIGURE 6-4. TYPICAL BATTERY CHARGING ALTERNATOR, STARTER MOTOR AND B− ISOLATING RELAY