Adjustment
8
Fig. 13 - 03
2
1
13
.04.03 Needle position to needle hole
Rule
The needle should pierce the middle of the needle hole exactly (with stitch length
regulation "0").
O Set the stitch length to "0" and move the needle bar to t.d.c.
O Loosen the screws 1, 2 and 3.
O Move the needle directly over the needle hole by turning the handwheel.
O Move the needle bar frame 4 according to the rule.
O Tighten the screws 1, 2 and 3.
4
3