Operation, Display and Application Examples PE6000 User Manual
26
3.6.5.2 Parameter Setting and Operation of JOG Running in DI Terminal Control
For equipment that requires frequent JOG operations, such as textile machine, it is more
convenient to control JOG running by using keys or buttons. To achieve convenient control,
perform the setting according to the following figure.
Figure 3-14 JOG running in DI terminal control
After performing the setting according to the preceding figure, press the FJOG button in stop
state of the AC drive. Then, the AC drive starts forward JOG. After you press the FJOG button
again, the AC drive decelerates to stop.
3.7 Setting the Running Frequency
The AC drive provides two frequency sources, namely, main frequency source X and
auxiliary frequency source Y. You can select one frequency source and switch over between the
two sources. You can also perform superposition on the two sources by setting the calculation
formula to meet different control requirements of different scenarios.
P8
-
00
P4-01
P4-02
P4-03
P4-04
P8
-
01
P8
-
02
P4-00
P0-02 = 1
P8-13 = 1