Rins171 Issue 6 Page 21
11.8 Setting Entry Time
To set the required Entry time. Enter
followed by the time required in seconds (
to seconds) followed by to accept.
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Entry time is factory set to 30 seconds.
11.9 Setting Exit Time
To set the required Exit time Enter
followed by the time required in seconds (
to seconds) followed by to accept.
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Exit time is factory set to 30 seconds.
11.10 Changing the Engineer Code
Enter
then the old Engineer Code - gives an audible acceptance tone
(Factory Set at 9999)
then
the new Engineer Code - gives an audible acceptance tone
then
the new Engineer Code again- gives an audible acceptance tone
If an incorrect key is entered an error tone will be given and the function ended.
11.11 Programmable Options
11.11.1 Programmable Output 1
Enter
followed by - for following options:
0 OFF (programmable output 1 not used).
1 PIR remote LED enable.
2 PIR latch memory.
3 Output switch 5 secs.
4 Output switch reflecting Setting and disarming of panel.
5 Follow zone. Refer to 11.1121 for Zone allocation.
6 Follow line fail.
7 Follow kiss off.
11.11.2 Programmable Output 2
Enter
followed by - for following options:
0 OFF (programmable output 2 not used).
1 PIR remote LED enable.
2 PIR latch memory.
3 Output switch 5 secs.
4 Output switch reflecting Setting and disarming of panel.
5 Follow zone. Refer to 11.11.22 for Zone allocation.
6 Follow line fail.
7 Follow kiss off.