4.2 Entry / Exit Mode
Entry When the panel is set and an Entry / Exit zone is triggered the Entry / Exit timer will begin to countdown.
During this period an Entry / Exit tone (single repeated bleep) will be produced by the internal sounder and
any zones which are programmed as Access zones will be ignored.
If either user code is entered before the end of the count down period the panel will return to ‘day’ mode.
If the timer is allowed to elapse before a user code is entered the panel will go into an alarm state. In this
case the system needs to be 'Unset'.
Exit With the panel unset, if a user code is entered the Entry / Exit timer will begin. If all the immediate zones are
clear, then the Entry / Exit tone will be heard. Leave the protected area by the predetermined Entry / Exit route.
As you trigger Access zones the tone will change temporarily to a repeated low tone. When all the zones are
clear, the Entry / Exit tone will continue again until the end of the time-out period. The panel will then be set.
5 ZONES
5.1 Engineer Programmable Zones
Entry / Exit This is a zone which allows limited-time access to the premises in order to Set or Unset the system.
Access This is a zone which, on Setting the panel, allows access to the Entry / Exit zone. However, if the
panel is set and an Access zone is triggered before an Entry / Exit zone then an alarm will be
generated immediately.
Immediate This is a zone, which will, when triggered, wil create an alarm when the panel is set.
Omit If a zone is programmed as an Omitted zone by the Engineer, then it is ignored by the panel. It allows
the user to continue to use the alarm system even if a fault has been discovered on one or more
zones.
Personal Attack Triggering of the Personal Attack (P.A.) zone will always cause a full alarm activation regardless of
whether or not the panel is set. The P.A. zone may be programmed as silent . A silent P.A. activation
will not cause the bell and strobe to operate but the central station will be informed of a P.A. activation.
Tamper The tamper zone may be programmed to give an internal siren or internal / external sounder in day
mode. In Set mode both sounders will operate.
Fire Triggering of the fire zone will activate internal and external sounders. A fire alarm is identified by a
three note rising sound which is easily distinguished from all other tones.
NOTE:
The Fire Zone is intended as an extra feature to the intruder alarm system and must not
be regarded as a total fire protection system.
24 Hour Zone Will cause an instant alarm when the panel is in Set or Unset mode. (Fire, Personal Attack and
Tamper are all 24 hour zones).
Latched Keyswitch
May be programmed to Set the System in one of the Set modes by using a latched mechanism.
Momentary
Keyswitch May be programmed to Set the System in one of the Set modes by momentarily pressing a switch.